check_circle_outlineSelected
Underground - Hard Rock
R1300G
|
Underground - Hard Rock
R1600H
|
Underground - Hard Rock
R1700
|
---|
Underground - Hard Rock
R1300G
Selected
Selected
|
|
|
---|---|---|
Engine | ||
Engine Model
|
||
Cat® 3306B DITA
Cat® 3306B DITA
|
Cat® C11
Cat® C11
|
Cat® C13
Cat® C13
|
Engine Power - Tier 3 Engine - ISO 14396:2002
|
||
-
|
271 HP
202 kW
|
361 HP
269 kW
|
Engine Power - ISO 14396:2002
|
||
157 HP
117 kW
|
-
|
-
|
Engine Power - Stage V Engine - ISO 14396:2002
|
||
-
|
-
|
345 HP
257 kW
|
Engine Power - VR Engine - ISO 14396:2002
|
||
-
|
271 HP
202 kW
|
361 HP
269 kW
|
Bore
|
||
4.75 in
120.7 mm
|
5.1 in
130 mm
|
-
|
Stroke
|
||
6 in
152.4 mm
|
5.5 in
140 mm
|
-
|
Displacement
|
||
640.75 in³
10.5 l
|
680.4 in³
11.1 l
|
-
|
Note (1)
|
||
Power ratings apply at a rated speed of 2,200 rpm when tested under the reference conditions for the specified standard.
Power ratings apply at a rated speed of 2,200 rpm when tested under the reference conditions for the specified standard.
|
Power ratings apply at a rated speed of 1,800 rpm when tested under the reference conditions for the specified standard.
Power ratings apply at a rated speed of 1,800 rpm when tested under the reference conditions for the specified standard.
|
Power ratings apply at a rated speed of 1,800 rpm for LRCs (VR and Tier 3/Stage IIIA) engines when tested under the reference conditions for the specified standard.
Power ratings apply at a rated speed of 1,800 rpm for LRCs (VR and Tier 3/Stage IIIA) engines when tested under the reference conditions for the specified standard.
|
Note (2)
|
||
All rating conditions are based on ISO/TR14396:2002, inlet air standard conditions with a total barometric pressure of 100 kPa (29.5 in Hg), with a vapor pressure of 1 kPa (0.295 in Hg), and 25° C (77° F). Performance measured using fuel to EPA specifications in 40 CFR Part 1065 and EU specifications in Directive 97/68/EC with a density of 0.845-0.850 kg/L @ 15° C (7.05-7.09 lb/gal @ 59° F) and fuel inlet temperature 40° C (104° F).
All rating conditions are based on ISO/TR14396:2002, inlet air standard conditions with a total barometric pressure of 100 kPa (29.5 in Hg), with a vapor pressure of 1 kPa (0.295 in Hg), and 25° C (77° F). Performance measured using fuel to EPA specifications in 40 CFR Part 1065 and EU specifications in Directive 97/68/EC with a density of 0.845-0.850 kg/L @ 15° C (7.05-7.09 lb/gal @ 59° F) and fuel inlet temperature 40° C (104° F).
|
All rating conditions are based on ISO/TR14396:2002, inlet air standard conditions with a total barometric pressure of 100 kPa (29.5 in Hg), with a vapor pressure of 1 kPa (0.295 in Hg), and 25° C (77° F). Performance measured using fuel to EPA specifications in 40 CFR Part 1065 and EU specifications in Directive 97/68/EC with a density of 0.845-0.850 kg/L @ 15° C (59° F) and fuel inlet temperature 40° C (104° F).
All rating conditions are based on ISO/TR14396:2002, inlet air standard conditions with a total barometric pressure of 100 kPa (29.5 in Hg), with a vapor pressure of 1 kPa (0.295 in Hg), and 25° C (77° F). Performance measured using fuel to EPA specifications in 40 CFR Part 1065 and EU specifications in Directive 97/68/EC with a density of 0.845-0.850 kg/L @ 15° C (59° F) and fuel inlet temperature 40° C (104° F).
|
Power ratings apply at a rated speed of 2,050 rpm for HRC (Stage V) engine when tested under the reference conditions for the specified standard.
Power ratings apply at a rated speed of 2,050 rpm for HRC (Stage V) engine when tested under the reference conditions for the specified standard.
|
Note (3)
|
||
Engine derate will commence at an altitude of 4500 m (14,763.7 ft).
Engine derate will commence at an altitude of 4500 m (14,763.7 ft).
|
No engine derating required up to 3048 m (10,000 ft) for Tier 3 Engine and 1828 m (6,000 ft) for VR Engine.
No engine derating required up to 3048 m (10,000 ft) for Tier 3 Engine and 1828 m (6,000 ft) for VR Engine.
|
All rating conditions are based on ISO/TR14396, inlet air standard conditions with a total barometric pressure of 100 kPa (29.5 in Hg), with a vapor pressure of 1 kPa (0.295 in Hg), and 25° C (77° F). Performance measured using fuel to EPA specifications in 40 CFR Part 1065 and EU specifications in Directive 97/68/EC with a density of 0.845-0.850 kg/L @ 15° C (59° F) and fuel inlet temperature 40° C (104° F).
All rating conditions are based on ISO/TR14396, inlet air standard conditions with a total barometric pressure of 100 kPa (29.5 in Hg), with a vapor pressure of 1 kPa (0.295 in Hg), and 25° C (77° F). Performance measured using fuel to EPA specifications in 40 CFR Part 1065 and EU specifications in Directive 97/68/EC with a density of 0.845-0.850 kg/L @ 15° C (59° F) and fuel inlet temperature 40° C (104° F).
|
Note (6)
|
||
-
|
-
|
Optional engine with emissions equivalent to Tier 3 and Stage IIIA is also available.
Optional engine with emissions equivalent to Tier 3 and Stage IIIA is also available.
|
Note (7)
|
||
-
|
-
|
Optional engine meeting the U.S. EPA Tier 4 Final and EU Stage V emission standards is also available.
Optional engine meeting the U.S. EPA Tier 4 Final and EU Stage V emission standards is also available.
|
Note (4)
|
||
-
|
Optional Ventilation Reduction package available.
Optional Ventilation Reduction package available.
|
No engine derating required up to 2895 m (9,500 ft) altitude for Stage V engines, 3505 m (11,500 ft) altitude for Tier 3/Stage IIIA engines, and 3200 m (10,500 ft) for Tier 2/Stage II VR engines.
No engine derating required up to 2895 m (9,500 ft) altitude for Stage V engines, 3505 m (11,500 ft) altitude for Tier 3/Stage IIIA engines, and 3200 m (10,500 ft) for Tier 2/Stage II VR engines.
|
Note (5)
|
||
-
|
Optional engine with emissions equivalent to U.S. EPA Tier 3 and EU Stage IIIA is also available.
Optional engine with emissions equivalent to U.S. EPA Tier 3 and EU Stage IIIA is also available.
|
Optional Ventilation Reduction package available.
Optional Ventilation Reduction package available.
|
Operating Specifications | ||
Weights | ||
Transmission | ||
Hydraulic Cycle Times | ||
Bucket Capacities | ||
Turning Dimensions | ||
Tires | ||
Service Refill Capacities | ||
Service Capacities - Not Refill | ||
Standards |
Price listed is Manufacturer's Suggested Retail Price, this price does not include shipping and handling, expedite charges, taxes, dealer installation costs or other dealer charges. Dealers set actual prices, including invoicing currency. The MSRP displayed is for the region selected.